Building Energy Code (BEC) currently in-force | Rules On The Efficient Use Of Energy In Buildings (no. 70/22 And 161/22) |
Date of BEC publication | 2000 |
BEC Jurisdiction | National |
Climate zone classification | Mixed, Humid |
Income Group | High income |
Type of BEC | Combination (Prescriptive/Performance-Based ) |
BEC Coverage | Passive design; Space Heating*; Space Cooling; Water Heating; Lighting |
GENERAL INQUIRIES
Slovenia
Ljubljana
* denotes coverage is through the European Ecodesign Directive
Types of Standards
On selection, change the data
Passive design (Residential)
Indicator | Mandatory Minimum Requirements |
---|---|
Maximum Solar Heat Gain Coefficient (SHGC) | .. |
Roof U-value (W/m?. K) | 0.15 |
Floors U-value (W/m?. K) | 0.35 |
External walls U-value (W/m?. K) | 0.18 |
Doors U-value (W/m?. K) | |
Air leakage prevention | .. |
Enforcement Mechanisms | .. |